FluorPen & PAR FluorPen
Quick, reliable and easy measurements in the field or laboratory
Handheld Devices
About...

The FluorPen FP 110 is a portable, battery-powered PAM fluorometer that enables quick and precise measurement of chlorophyll fluorescence parameters in the laboratory, greenhouse, or in the field. It can be effectively used for studying photosynthetic activity, stress detection, herbicide testing, or mutant screening. The affordable price and straight-forward two-button operation makes the FluorPen a perfect tool for research and for teaching photosynthesis.

The PAR-FluorPen FP 110 is an extended version of FluorPen FP 110 that incorporates an integrated light meter for direct digital readouts of Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm.

Key Features

  • Rapid and accurate measurement of photosynthetic parameters
  • Photosynthetically Active Radiation measurements
  • Leaf-clip for dark adaptation
  • Fast chlorophyll fluorescence induction kinetics measurements
  • Lab and field applications


  • Rugged and compact device
  • Easy-to-use two-button operation
  • Comprehensive software for data processing
  • USB and Bluetooth communication for data transfer
  • Integrated GPS module

FluorPen FP 110 and PAR-FluorPen FP 110-LM

FluorPen FP 110 is a portable, battery-powered PAM fluorometer that enables quick and precise measurement of chlorophyll fluorescence parameters in the laboratory, greenhouse, or in the field. It can be effectively used for studying photosynthetic activity, stress detection, herbicide testing, or mutant screening. Affordable price and straight-forward two-button operation makes the FluorPen a perfect tool for teaching photosynthesis.

PAR-FluorPen FP 110 is extended version of FluorPen FP 110, which incorporates an integrated Light Meter for direct digital readouts of Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm, the span in which plants use energy during photosynthesis. PAR is measured as Photosynthetic Photon Flux Density (PPFD), which is indicated by units of quanta (photons) per unit time per unit surface area. The sensor has a uniform response to photons within the 400 - 700 nm waveband. Instant readouts are provided as average values of 20 measurements.

Measured data are sequentially stored in the internal FluorPen memory. Data transfer to a PC is via USB or Bluetooth communication. Comprehensive FluorPen 1.1 software provides data transfer routines and many additional features for data presentation in tables and graphs.

Different leaf-clips for gentle but firm sample holding are available:

  • standard leaf-clip is suitable for experiments where short term dark adaptation is needed (version S);
  • detachable leaf-clips are suitable for experiments where long term dark adaptation is needed (version D);
  • custom optical probe is used in online FP version providing autonomous unattended measuring in lab conditions (version P);
  • custom open-window leaf-clips are suitable for measurements in ambient light (version X).

APPLICATIONS


  • Photosynthesis research
  • Screening & Characterization of photosynthetic mutants
  • Field studies
  • Stress detection
  • Agriculture & forestry
  • Herbicide testing
  • Education

FLUORPENS MEASURE


  • Ft - continuous fluorescence yield in non-actinic light. Ft is equivalent to F0 if the leaf sample is dark-adapted.
  • QY - photosystem II Quantum Yield. QY is equivalent to Fv/Fm in the dark-adapted samples and to Fv'/Fm' in the light-adapted samples.
  • OJIP - Chlorophyll Fluorescence Induction Kinetics. The OJIP curves enable observing major changes that occur during exposure of plants to high irradiance.
  • NPQ - Non-Photochemical Quenching. The NPQ protocol is the most typically used measuring approach to quantify photochemical and nonphotochemical quenching. The measurement should be performed with a dark-adapted sample.
  • Light Curve (QY) - Photosystem II Quantum Yield estimated from fluorescence that is measured sequentially in several different light levels.
  • PAR - Photosynthetically Active Radiation measured as Photosynthetic Photon Flux Density (PPFD) (only in PAR-FluorPen FP 110)

SOFTWARE


  • FluorPen 1.1 software (Windows 7 or higher compatible)
  • Real-time and remote control functions
  • Bluetooth and USB communication
  • Visualization and data transfer routines to Microsoft Excel (optional)
  • GPS mapping

Versions

Generally, all FluorPen/PAR-FluorPen versions measure the same pre-programmed fluorescence protocols and the single versions differ only in the type of used sample holder (S – standard, firmly attached leaf-clip; D – detachable leaf-clip; P – measuring probe; X – any custom-made sample holder).

Each FluorPen/PAR-FluorPen version is equipped with two communication modules – USB and Bluetooth – as well as with an in-built GPS module.

Below is detailed description of single FluorPen/PAR-FluorPen versions - with emphasis on recommended application for each version.

  • FluorPen FP 110/S and PAR-FluorPen FP 110/S
  • This version is equipped with a standard, firmly attached leaf-clip (see the picture below). It is mostly recommended for indoor experiments focusing on plants cultivated in pots, which can easily be moved to a dark place for dark adaptation.

    The PAR version enables measuring Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm.

  • FluorPen FP 110/D and PAR-FluorPen FP 110/D
  • This version is equipped with an optical head that allows use of detachable leaf-clips (see the picture below). These clips are intended for easy dark-adaptation of measured samples prior to measurement. The “D” version is highly recommended for field experiments. Users put the clips on selected leaves, wait required time of dark-adaptation and then measure one leaf after another (please note that detachable leaf-clips can damage very small leaves, for instance, juvenile Arabidopsis plants).

    The PAR version enables measuring Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm.

  • FluorPen FP 110/P and PAR-FluorPen FP 110/P
  • This version is equipped with a measuring probe and a thread for tripod attachment. The measuring probe ensures contactless sample measurement and measurement of light adapted samples. This version is recommended for automated long-term monitoring experiments.

    The PAR version enables measuring Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm.

  • FluorPen FP 110/X and PAR-FluorPen FP 110/X
  • The “X“ version is mounted with a custom-made sample holder; ordering of this version must be consulted with PSI staff prior to the order – please contact us on info@psi.cz. This version may also be offered with an optional PAR sensor for measuring of Photosynthetically Active Radiation (PAR) in the range from 400 to 700 nm.

In case of additional questions, please contact us on info@psi.cz or support@psi.cz


Accessories

Detachable Leaf-Clips

Supplementary detachable leaf-clips for use with the FluorPen FP 110/D and PAR-FluorPen FP 110/D. 10-piece set.

Control and Data Unit for Handheld Devices

Small, portable notebook (type according to current availability on the market).

Mini-Tripod

Small (table-top like) tripod is intended to be used with the FluorPen FP 110/P.
Note: in other FluorPen/PAR-FluorPen versions thread for tripod mounting is not integrated. However, it may be integrated on request. Inquire for pricing on info@psi.cz

Substitute USB Communication Cable

Substitute USB cable allowing connection between the "pen" devices and a PC (the device is delivered with one USB cable, which is included in the device price).

Self-Adhesive Rubber Pads

One set includes 10 solid pads (to be attached to the clip) and 10 pads with an opening (to be attached at the optical head). The self-adhesive rubber pads are only sold with the “S” version of FluorPens/PAR FluorPens.

Set of Replacement Joint Rings

10-piece set O-rings 14,00 x 1,00 NBR 70 Sh for use with the FluorPen FP 110/D or PAR-FluorPen FP 110/D.

[h1]Documents[/h1] [list] [*][b]FluorPen and Monitoring Pen Manual (pdf)[/b] [*][b]FluorPen Explain (pdf)[/b] [*][b] Technical specifications (pdf)[/b] [/list] [h1]Software[/h1] [list] [*][b]FluorPen 1.2.0.0 software (exe)[/b] [*][b]USB Driver for FluorPen and PAR FluorPen (exe)[/b] [/list] [h1]Promotional Materials[/h1] [list] [*][b] Handheld Devices brochure (pdf)[/b] [/list]
Handheld devices

FluorPen Quickstart Guide

Pricing


FluorPen
Version Characteristics Price
FluorPen FP 110/S Handheld PAM fluorometer with integrated GPS module, USB, Bluetooth communication and dedicated software. Measures Ft, QY, OJIP, NPQ and LC.
Equipped with a standard leaf-clip.
2,699 €
FluorPen FP 110/D Handheld PAM fluorometer with integrated GPS module, USB, Bluetooth communication and dedicated software. Measures Ft, QY, OJIP, NPQ and LC.
Adapted for use with detachable leaf-clips; leaf clips sold separately.
2,699 €
FluorPen FP 110/P Handheld PAM fluorometer with integrated GPS module, USB, Bluetooth communication and dedicated software.Measures Ft, QY, OJIP, NPQ and LC.
Intended for autonomous use in indoor conditions. It features a plastic case,
measuring probe and thread for tripod attachment.
2,915 €
FluorPen FP 110/X Handheld PAM fluorometer with integrated GPS module, USB, Bluetooth communication and dedicated software. Measures Ft, QY, OJIP, NPQ and LC.
The “X“ version is mounted with custom-made leaf-clip.
Enquire for price

PAR-FluorPen FP 110/S Includes an integrated Light Meter, GPS module, USB and Bluetooth
communication and dedicated software. Measured parameters: PAR, Ft, QY,
OJIP, NPQ, LC. Equipped with a standard leaf-clip.
2,999 €
PAR-FluorPen FP 110/D Includes an integrated Light Meter, GPS module. USB and Bluetooth
communication and dedicated software. Measured parameters: PAR, Ft, QY, OJIP,
NPQ, LC. Adapted for use with detachable leaf-clips; leaf clips sold separately.
2,999 €
PAR-FluorPen FP 110/P Handheld fluorometer with integrated Light Meter, GPS module, USB, Bluetooth
communication and dedicated software. Measured parameters: PAR, Ft, QY, OJIP,
NPQ, LC. The “P“ version uses measuring probe
and thread for tripod attachment.
3,190 €
PAR-FluorPen FP 110/X Handheld fluorometer with integrated Light Meter, GPS module, USB, Bluetooth communication and dedicated software. Measured parameters: PAR, Ft, QY, OJIP,
NPQ, LC. The “X“ version is mounted with custom-made leaf-clip.
Enquire for price

Accessories

Replacement of the Battery
and Device Recalibration *
Replacement of the internal rechargeable battery
and the device recalibration.
485 €
Detachable Leaf-Clips * 10-piece set of detachable leaf-clips for use
with the FluorPen FP 110/D or PAR-FluorPen FP 110/D.
175 €
Set of Replacement Joint Rings * 10-piece set O-rings 14,00 x 1,00 NBR 70 Sh for use
with the FluorPen FP 110/D or PAR-FluorPen FP 110/D.
11 €
Mini Tripod * Small (table-top like) tripod is intended to be used
with the FluorPen FP 110/P.
35 €
Control and Data Unit
for Handheld Devices *
Small, portable notebook (type according to current availability on the market). 520 €
Substitute USB
Communication Cable *
Substitute USB cable allowing connection between the "pen" devices
and a PC (the "pen" device is delivered with one USB cable).
45 €
Self-Adhesive Rubber Pads
for FluorPens
One set includes 10 solid pads (to be attached to the clip) and 10 pads
with an opening (to be attached at the optical head).The self-adhesive rubber
pads are only sold with the “S” version of FluorPens/PAR FluorPens.
35 €